Distributor Contact Gap- Stag
Please note the Distributor Contact Gap clearance has been amended from 0.010″ – 1.012″ to 0.014″- 0.016″. Consequently, the dwell angle has also changed from 34° – 37° to 29 1/2° – 33 1/2°. This new setting applies to all Triumph Stags.
The ignition timing of 11° BTCD static (5° ATCD at idle) remains unchanged.